check weigher

For stock management, you can carry out control registration with a connected scale.

Note: Project work subject to planning

This is an area that requires detailed project planning.

The Hypersoft system is a flexible standard solution that can be used in a variety of configurations. The correct implementation of the functions described here requires specialist expertise and a clear comparison of your requirements and expectations.

Please note that not all Hypersoft employees or partners are trained to the same extent in each of these labelled subject areas.

For this reason, we characterise certain content as "project work requiring planning". We would like to ensure that you contact your Hypersoft sales partner or Hypersoft Support at an early stage in order to carry out the necessary planning and coordination.

This structured approach enables us to carefully analyse your requirements and implement them in a targeted manner.


Element / Switch Function / Description
Select balance type

To operate the current Sartorius balance, you must set the Free balance type with a baud rate of 9600.

Then select the interface used and you can connect the balance and use it for the Hypersoft Suite.

Small checkweigher:

Large checkweigher:

Core scale...

Tested Type: "Core PCB 6000"

The balance must be configured as follows:

According to the manual, enter the menu, hold F + %, then switch on the balance.

Next parameter with "TOL" key

Change value with "TARE" key

Save value with "0" key

Exit menu "F"-key

Important: The balance transmits when the weight has been completely determined ( beep sounds ) AND the sample is removed from the balance. As long as the scale is loaded, it does not output a result.

Set the parameters as follows:

Set InC to "Inc 50" ( weighing range 0.5 gram )

Set AU to "on" ( send after weighing )

Set B 4800 to "9600" Baud

tP or LP50, if LP50 is active, change to tP

ACC to off ( summing mode )

Pr to AU Set Pr ( Data output of stable weight values)

Port: Select the interface to which the device is connected.

baud rate

ESC Sequence

End Detection

These values are automatically entered in the Hypersoft scales.

Details of the sales scale...

This is the old method for connecting sales scales (sales scales without special approvals). Each station to which a sales scale is connected must have the corresponding setting at the end of the station details.

Use the new connection of sales scales as described under Sales Scale Sales scale /Check-Out scale.


Back to the parent page: Hypersoft POS Connections